|
Product Details:
Payment & Shipping Terms:
|
Standard: | ASTM F136、ASTM F67 ELI | Application: | Medical Use |
---|---|---|---|
Item: | Gr.5 Eli Polished Medical Titanium Rod ASTM F67 ELI For Medical Use | Product Name: | ASTM F136 Ti6Al4V-Eli Titanium Rod Bars For Medical Use ELI |
Key Word: | Titanium Bar,titanium Rod,Titanium Grade 5 Round Bar | Polished Surface: | Polished Surface (H11, H9, H8) |
Highlight: | Gr5 Eli Polished Titanium Rod,Titanium Industrial Bar ASTM F67,Medical Pure Titanium Bar |
Gr.5 Eli Polished Medical Titanium Rod ASTM F67 ELI For Medical Use
Item Name | ASTM F136 Ti6Al4V-Eli Titanium rod bars for medical use ELI |
Application | medical use |
Type | GR1, GR5, 6AL4V Eli, GR23 |
Standard | ASTM F136,ASTM F67 ELI |
Certificate | ISO 9001:2008 |
Manufacturing process: | Hot forging hot rolling turning (polishing) |
Supply Ability | 10 Tons per Month |
Gr.5 titanium cake, pure titanium forging, titanium block, Gr.5 titanium forging_ Titanium and titanium alloy bars are processed according to the drawing, with large quantity and low price
Grade: GR1, GR2, GR3, GR5, GR7, GR12
GB: GB/T2965-2007, GB/T13810, Q/BS5331-91
American standard: ASTM B348, ASTM F136, ASTM F67, AMS4928
1, Reference standards
1: GB 228 Metal Tensile Test Method
2: GB/T 3620.1 Titanium and Titanium Alloy Number and Chemical Composition
3: GB/T3620.2 Chemical Composition and Allowable Deviation of Titanium and Titanium Alloy Processed Products
4: GB 4698 Methods for Chemical Analysis of Sponge Titanium, Titanium and Titanium Alloys
2, Technical requirements for medical titanium rods
1: The chemical composition of titanium and titanium alloy bars shall comply with the provisions of GB/T 3620.1. When repeated inspection is required, the allowable deviation of chemical composition shall comply with the provisions of GB/T 3620.2.
2: The diameter or side length of hot worked titanium bar and its allowable deviation shall comply with the provisions in Table I.
3: After hot processing, after turning (grinding) titanium bars and cold rolling, the allowable diameter deviation of cold drawn titanium bars shall comply with the provisions in Table II.
4: The out of roundness of the turned (ground) titanium bar after hot working shall not exceed half of its dimensional tolerance.
5: The unfixed length of titanium bars in the processing state is 300-6000mm, and the unfixed length of bars in the annealing state is 300-2000mm. The fixed length or multiple length shall be within the range of unfixed length. The allowable deviation of fixed length is+20mm; The multiple length shall also be included in the cut amount of the bar, and each cut amount shall be 5mm. The fixed length or multiple length shall be indicated in the contract.
Medical titanium rod
Specification: rolled ¢ 8.0 --- 40mm × L; Forged ¢ 40 --- 150mm × L
Metallographic structure of titanium rod for titanium: the grain size of pure titanium is not less than 5, and TC4 titanium alloy conforms to A1-A9
Titanium rod surface: black leather surface, polished surface, polished surface (H11, H9, H8)
Performance of medical titanium rod (refer to GB/T13810-2007, ASTM F67/F136).
Main brand: TA1 TA2 TA3 TA4 TA5 TA6 TA9 TA10 TC1 TC4 TC6 TC11 GR.1 GR.2 GR.3 GR.4 GR.5 GR.7 GR.12 Ti-6AL-4V
Supply status: annealed (M) cold working (Y) hot working (R)
Contact Person: Ms. Grace
Tel: +8613911115555
Fax: 86-0755-11111111